T12 Thermometer
precise and stable MEASUREMENT
Platinum Resistance Thermometer
Our MBW CALIBRATION™ T12™ Thermometer is a precise and stable platinum resistance thermometer (PRT) multi-channel temperature measurement system. Using a custom designed high quality measurement circuit, 24 bit analog to digital converters and multiplexor sampling; the T12 provides 12 channels of precise temperature data for validation and calibration engineers. T12 repeatedly scans all 12 channels and the low and high range internal reference resistors, with user configurable excitation current. Employing a full reversal current source, the T12 eliminates polarity sensitive errors inherent in DC measuring techniques.
The GeckoR2™ software supplied allows each channel to be individually configured with ITS-90 or Callendar-Van Dusen coefficients for direct conversion of resistance to temperature. The T12 connects to a PC through an RS-232 Interface. An RS232 to USB converter is included. There are four versions available, the T12, T12-S, T12-SE and the T12-E. The new ‘S’ versions feature Smart Connectors that are configured usingGeckoR2with coefficients and calibration corrections, probe position and unique identifiers.
A typical application of the T12 Thermometer is the validation of temperature uniformity in climatic chambers, incubators, ovens and humidity generators. In combination with dew point measurement data from an MBW dew point mirror, the T12 can also be used to determine relative humidity uniformity directly within GeckoR2 software. This means that development, validation and calibration engineers can directly assess performance and observe the effects of changes in system settings in real time.
- Twelve channel temperature measurement
- Integrated scanner
- High precision, stability and repeatability
- Negligible temperature coefficient
- Internal reference resistors
- PC software for system control and data acquisition
- Simple to configure and use
KEY SPECIFICATIONS
T12-S
- Temperature measuring range: -200…246 °C
- Resistance: 1…194 Ω
- Accuracy (@ 23 °C): ≤ ± 5 mK
- Resolution 0.12 mK
T12-SE
- Temperature measuring range: -200…246 °C
- Resistance: 1…194 Ω
- Accuracy (@ 23 °C): ≤ ± 20 mK
- Resolution 0.12 mK
T12
- Temperature measuring range: -200…800 °C
- Resistance: 1…380 Ω
- Accuracy (@ 23 °C): ≤ ± 2 mK
- Resolution 0.12 mK
T12-E
- Temperature measuring range: -200…800 °C
- Resistance: 1…380 Ω
- Accuracy (@ 23 °C): ≤ ± 20 mK
- Resolution 0.12 mK
APPLICATIONS
- Climatic Chamber Validation
- Temperature Calibration
- Calibration Systems
- Energy performance testing
For a complete range of analytical instrumentation, applications, systems, and service options, we will work to match your needs and budget and provide the optimal, and most stable process analysis solution for your application.