HALO 3 D2O/HDO
Deuterium (D2 or 2H2), also known as “heavy hydrogen”, is used in a variety of applications, including industrial and university research comparisons between the hydrogen and deuterium in deposited film analysis, rapid thermal anneals for certain semiconductor devices, and optical fiber manufacturing to eliminate the water peak in the telecom E-band.
Whether for process control or quality assurance, gas suppliers need accurate, low-level contaminant monitoring to ensure deuterium purity, especially for trace D2O (heavy water) and HDO (semi heavy water). The HALO 3 D2O/HDO analyzer offers unparalleled accuracy and reliability for your deuterium purity analysis. Compact and easy to use, this analyzer features our proven Cavity Ring-Down Spectroscopy technology to effortlessly detect single-digit ppb levels of D2O and HDO in your sample.
Users enjoy freedom from periodic sensor maintenance, and with no calibration gases required, operating costs are nearly eliminated. With drift-free stability and rapid response time, the HALO 3 D2O/HDO analyzer is ideal for continuous, online gas monitoring that is critical to process control in gas and chemical industries or anywhere purity is a necessity.
Detection and Matrix | Range | LDL (3σ) | Precision (1σ) @ zero |
---|---|---|---|
D2O in D2 | 0 – 20 ppm | 3 ppb | 1.0 ppb |
D2O in N2 | 0 – 50 ppm | 7 ppb | 2.5 ppb |
HDO in D2 | 0 – 30 ppm | 5 ppb | 2 ppb |
HDO in N2 | 0 – 40 ppm | 6 ppb | 2 ppb |
Performance | |
---|---|
Operating range | See Detection Capability table |
Detection limit (LDL, 3σ/24h) | See Detection Capability table |
Precision (1σ, greater of) | ± 0.75% or 1/3 of LDL |
Accuracy (greater of) | ± 4% or LDL |
Speed of response | < 1 minute to 90% |
Environmental conditions | 10°C to 40°C, 30% to 80% RH (non-condensing) |
Storage temperature | -10°C to 50°C |
Gas Handling System and Conditions | |
Wetted materials | 316 stainless steel (optional corrosion-resistant material), 10 Ra surface finish |
Gas connections | 1/4″ male VCR inlet and outlet |
Leak tested to | 1 x 10-9 mbar l / sec |
Inlet pressure | 10 – 125 psig (1.7 – 9.6 bara) |
Flow rate | 0.05 to 1.8 slpm |
Sample gases | D2 and N2 |
Gas temperature | Up to 60°C |
Dimensions | |
Standard sensor | 8.73″ x 8.57″ x 23.6″ (222 mm x 218 mm x 599 mm) |
Sensor rack (fits up to two sensors) | 8.73″ x 19.0″ x 23.6″ (222 mm x 483 mm x 599 mm) |
Weight | |
Standard sensor | 28 lbs (12.7 kg) |
Electrical and Interfaces | |
Platform | Max series analyzer |
Alarm indicators | 2 user programmable, 1 system fault, Form-C relay |
Power requirements | 90 − 240 VAC, 50/60 Hz |
Power consumption | 40 Watts max. |
Signal output | Isolated 4–20 mA per sensor |
User interfaces | 5.7″ LCD touchscreen, 10/100 Base-T Ethernet |
USB, RS-232, RS-485, Modbus TCP (optional) | |
Data storage | Internal or external flash drive |
Certification | CE Mark |
Patents | |
U.S. Patent #7,277,177 |
Serani™ Analyzer Interface Software offers users a new way to access their analyzer remotely from any computer or laptop. Compatible with most HALO, Spark, Tiger-i, CO-rekt and ALOHA H2O series analyzers.