TRACE S-1000

Trace Sulfur Gas Analyzer

TOTAL SULFUR-NITROGEN ANALYZERS 

For Reliable Trace Sulfur Measurements

Our ATOM INSTRUMENT™ Trace S-1000™ Trace Sulfur Analyzer is an online process analyzer utilizing patented Excimer UV Fluorescence (EUVF) Technology to measure Total Sulfur in a variety of refinery process applications.  The Trace S-1000 with patented Excimer UV fluorescence technology is a field proven technology that utilizes an excitation wavelength that achieves high detection sensitivity and detector stability.

The Trace S-1000 Trace Sulfur Analyzer is an excellent fit for applications in the 0-1ppm range and is exceptionally stable, even at concentrations less than 1 ppm. The Trace S-1000 is designed for outdoor installation and use in harsh environments as may be required by the refining (LPG), gas processing (NGL) and natural gas industries.

Trace S-1000 Trace Sulfur Analyzer provides complete analysis of all sulfur compounds potentially present in process gas streams and not just a few selected sulfur compounds as with some GC/TDL applications. Calibration and validation are seamlessly incorporated with an optional calibration switching configuration and associated software for easy compliance or verification testing.

  • Low concentration total sulfur analysis (100 PPB – 1 PPM) 
  • High speed analysis and response time
  • User defined data averaging
  • Low utility consumption
  • Compact instrument footprint
  • Does not require installation in shelter

INDUSTRIES

The Trace S-1000 Trace Sulfur Analyzer is used in a variety of industries where trace-level analysis of elements is required. Some examples of industries that use the Trace S-1000 analyzer include:

  • Environmental monitoring: Can be used to analyze trace elements in environmental samples, such as water or soil, to monitor pollution or contamination.
  • Petrochemicals and refineries: Can be used to analyze trace elements in crude oil, natural gas, and other petrochemical products to monitor impurities and ensure product quality.
  • Semiconductor manufacturing: Can be used to analyze trace impurities in semiconductor materials, such as silicon wafers, to ensure product quality and performance.
  • Pharmaceutical manufacturing: Can be used to analyze trace elements in pharmaceutical products, such as drug formulations and raw materials, to ensure purity and quality.

APPLICATIONS

The Trace S-1000 Trace Sulfur Analyzer is used in a variety of applications where trace-level analysis of elements is required. Some examples of applications that use the Trace S-1000 analyzer include:

  • Elemental analysis of environmental samples: Can be used to analyze trace elements in water, soil, air, and other environmental samples to monitor pollution and contamination.
  • Quality control in petrochemicals and refineries: Can be used to analyze trace elements in crude oil, natural gas, and other petrochemical products to monitor impurities and ensure product quality.
  • Analysis of semiconductor materials: Used to analyze trace impurities in semiconductor materials, such as silicon wafers, to ensure product quality and performance.
  • Quality control in pharmaceuticals: Used to analyze trace elements in pharmaceutical products, such as drug formulations and raw materials, to ensure purity and quality.
  • Food and beverage analysis: Can be used to analyze trace elements in food and beverage products to ensure quality and safety.

APPLICATIONS

  • LPG
  • Natural Gas
  • Reforming and Isomerization
  • Catalyst Protection
  • Blending Operations
  • Flare and Stack Gas
  • Refinery Grade Fuels

EASY TO INSTALL & USE

The Trace S-1000 Trace Sulfur Analyzer with EUVF is a field-proven technology that utilizes an excitation wavelength that achieves high detection sensitivity and detector stability. The Trace S-1000 is an excellent fit for applications in the 0-100 ppm range and is exceptionally stable, even at concentrations less than 1 ppm. The Trace S-1000 is designed for outdoor installation and use in harsh environments as may be required by the refining (LPG), gas processing (NGL) and natural gas industries.  The Trace S-1000 allows stable and accurate analysis at both high and low sulfur concentrations below 1 PPM. Taking advantage of the standard 100 second analysis cycle time, any number of standard analyses up to 10 sequential results can be seamlessly averaged to provide a more consistent and reliable concentration measurement, allowing optimization of low range detection performance and analyzer response time depending on application requirements.

To Top

OUR TOTAL SULFUR – NITROGEN ANALYZERS

XTH-2000™ with “Boat Injection Module”

ATOM INSTRUMENT™ Laboratory Analyzer for Total Sulfur & Total Nitrogen

XT-2000™

ATOM INSTRUMENT™ Laboratory Analyzer for Total Sulfur & Total Nitrogen
Process Insights_ATOM Instrument_XT 2000 Analyze

SGA-1000™

ATOM INSTRUMENT™ Sulfur in Gas Analyzer
Process Insights_ATOM SGA-1000 Analyzer

SLA-1000™

ATOM INSTRUMENT™ Sulfur in Liquid Analyzer
Process Insights_ATOM SGA-1000 Analyzer

FGA-1000™

ATOM INSTRUMENT™ Flare Gas Analyzer for Total Sulfur
Process Insights_ATOM SGA-1000 Analyzer

LAS-1000™

ATOM INSTRUMENT™ Liquid Autosampler
Process Insights_ATOM LAS-1000

EIM-1000™

ATOM INSTRUMENT™ External Injection Module
Process Insights_ATOM EIM-1000 EXTERNAL INJECTION MODULE
To Top

Questions? We’re here to help.