Skip to main content

G-SST VAPOR PROCESS PROBE

Vapor Process Probe

Compatible with ClearView Hydrogen Peroxide Vapor Analyzer

For hydrogen peroxide or other vapor applications, our GUIDED WAVE™ 50 cm G-SST Vapor Process Probe provides an efficient, simple and easy interface between the vapor chamber, and our Hydrogen Peroxide Vapor analyzers. The probe clamps into a standard 2-inch Tri-Clover® sanitary fitting and can be mounted in the vapor chamber, feed line, or return line. Alternatively, a flangeless version of the G-SST Vapor Probe is available for mounting inside the chamber, with a fiber feed through sanitary cap. 

Primary Advantages New 50 cm Pathlength G-SST Over the Previous 25 cm, 28.3 cm and the Original 50 cm G-SST Vapor Process Probe

  1. The double pass beam design (folded path) provides two times the beam interaction with the gases in the sterilizer chamber. This increases the achievable signal-to-noise making for a more accurate and stable measurement. Since the absorbance of water and Hydrogen Peroxide vapor is very weak, this is a significant improvement in the measurement accuracy.
  2. The optics are sealed behind a window which isolates the lenses from the sterilization chamber; thus the probe is not sensitive to index of refraction changes. This makes the measurements more stable under widely varying conditions of deep vacuum to high concentrations of water and hydrogen peroxide vapor.
  3. The open probe  structure allows the probe to be quickly serviced by a technician. With the lenses behind an o-ring sealed window, there is no adhesive degradation, increasing the service life of the probe.

Features

  • Glass windows protect optical surfaces
  • High optical efficiency, > 50% transmission
  • Long pathlength, 50cm for greater accuracy and stability
  • Rugged design
  • SMA 905 fiber optic interface, all fiber sizes
  • Single-sided design, no need for fiber cable feedthroughs
  • Can be installed in vapor feed, return lines or sterilization chamber
  • Works in vacuum (10-5 Torr) or up to 2 atm absolute
  • Operates in an environment from 0°C to 90°C

Options

  • 2-inch (50.8 mm) Tri-clover port
  • Electropolished 316 stainless steel or anodized aluminum body material
To Top






Provides efficient, simple and easy interface between the vapor chamber, and our Hydrogen Peroxide Vapor (HPV) analyzers 

Process Insights_Guided Wave G-SST Vapor Process Probe

FIBER INSTRUCTIONS

Fiber Optic Cable Instructions for High-Performance Spectroscopy

APPLICATION SUPPORT

We offer many high performance, affordable, turnkey solutions for your application.


NIR & UV-VIS Process and Lab Analyzers 

Customized, innovative analyzers designed to meet your specific process and safety needs.

FTIR FT-NIR Lab & Process Analyzers




Flow Cells & Probes

Process Insights_Guided Wave_SST – Single-Sided Transmission Process Probe
SST
GUIDED WAVE™ Gold Brazed Single-Sided Transmission Probe
SST LAB
GUIDED WAVE™ Gold Blaze Sealed QC Lab Transmission Probe

Process Insights_Guided Wave_O-SST O-Ring Single Sided Transmission Probe For Process Sampling
O-SST
GUIDED WAVE™ O-Ring Single Sided Transmission Probe
RTD-SST
GUIDED WAVE™ SST Probe with Built-in RTD for Process Monitoring with Temperature Measurement
G-SST Vapor Probe
GUIDED WAVE™ Probe for Precise Measurements of Gas Streams such as Hydrogen Peroxide & Water Vapor
Shuttle Process Probe
GUIDED WAVE™ Two Coupled Insertion Probes for Easy Maintenance without Process Flow Interruption
Turbidity Process Probe
GUIDED WAVE™ Probe for Haze or Turbidity (NTU) Measurements with ClearView® db
MPFC Multi-Purpose Process Flow Cell
GUIDED WAVE™ Flow Cell Alternative to Insertion Probe
Process Insights_Guided Wave_Heated Flow Cell
Heated Multi-Purpose Flow Cell
GUIDED WAVE™ Flow Cell for Heating/Cooling Fluid to Maintain Temperature of Preconditioned Sample
Axial Process Flow Cell
GUIDED WAVE™ Long Path Flow Cell for Low Concentration
Gas Flow Cell
GUIDED WAVE™ Flow Cell for Measuring Online Gas Phase Samples by Spectroscopy
HSFC High Safety Process Flow Cell
GUIDED WAVE™ Flow Cell for Extremely Hazardous Samples, Designed with Leak Prevention
Teflon Flow Cell
GUIDED WAVE™ Flow Cell for Corrosive or Intolerant Sample Streams
Teflon PFA/PEEK Flow Cell
GUIDED WAVE™ Flow Cell for Sample Streams Incompatible w/ Metal Compounds (HF Semiconductor Baths)
Teflon Axial Flow Cell
GUIDED WAVE™ Flow Cell for Sample Streams in Highly Corrosive Processes | Trace Metal Contamination Sensitivity
Turbidity Flow Cell
GUIDED WAVE™ Flow Cell for At-Line Measurements Where a Direct Insertion Probe is Not Practical
Cuvette Holders
GUIDED WAVE™ Cuvette Holder for QC Lab Sample Interface
PROBE EXTRACTOR MECHANISM
GUIDED WAVE™ Extractor for Controlled Extraction/Insertion of In-Line Probe
THERMALLY STABLE NIR FIBER OPTIC CABLE
GUIDED WAVE™ Fiber for Signal Stability & Low Noise in Remote Spectroscopy
DEEP UV-VIS FIBER OPTIC CABLE
GUIDED WAVE™ High Optical Throughput Fiber for Wavelengths Down to 200 nm
To Top

OUR NIR-UV-VIS PROCESS AND LAB ANALYZER SPECTROMETER SOLUTIONS

NIR-O™

GUIDED WAVE™ Full Spectrum Near-Infrared (NIR) Process Analyzer
Process Insights_guided wave- NIR-O_process analyzer_GUIDED WAVE NIR UV-VIS process and lab analyzer spectrometers

LAB NIR-O™

GUIDED WAVE™ Full Spectrum Near-Infrared (NIR) Lab Analyzer
Process Insights_guided wave - Lab-NIR-O_analyzer_GUIDED WAVE NIR UV-VIS process and lab analyzer spectrometers

508 UV-VIS™ PROCESS ANALYZER

GUIDED WAVE™ UV-VIS Full Spectrum Process Analyzer
Process Insights_guided wave-M508-analyzer_analyzer_GUIDED WAVE NIR UV-VIS process and lab analyzer spectrometers

LAB 508 UV-VIS™ Benchtop

GUIDED WAVE™ UV-VIS Full Spectrum Benchtop Analyzer
Process Insights_Guided Wave_Model 508plus benchtop_analyzer_GUIDED WAVE NIR UV-VIS process and lab analyzer spectrometers

ClearView® db Dual Beam Photometer

GUIDED WAVE™ VIS-NIR Dual-Beam Photometer
Process Insights_Guided Wave ClearView-db_analyzer_GUIDED WAVE NIR UV-VIS process and lab analyzer spectrometers

ClearView® db Hydrogen Peroxide Vapor Analyzer System

GUIDED WAVE™ Hydrogen Peroxide Vapor Monitor
Process Insights_Guided Wave Hydrogen Peroxide Vapor Analyzer HPVA Photometer Systems

APHA/Platinum-Cobalt Color Analyzer System

GUIDED WAVE™ Complete Analytical System for Measuring APHA Color (Platinum-Cobalt ASTM D1209)
Process Insights_Guided Wave ClearView-db-enclosures-400x135

ASTM Color Analyzer System

GUIDED WAVE™ Complete Analytical System for Measuring ASTM Color (ASTM D1500, ASTM D1524)
Process Insights_Guided Wave ClearView-db-enclosures-400x135

Saybolt Color Analyzer System

GUIDED WAVE™ Complete Analytical System for Measuring Saybolt Color (ASTM D156, ASTM D604)
Process Insights_Guided Wave ClearView-db-enclosures-400x135

Turbidity Analyzer System

GUIDED WAVE™ VIS-NIR Dual-Beam Photometer

Probes & Flow Cells / Fiber & Accessories

GUIDED WAVE™ Accessories for NIR-UV-VIS & FT-NIR Analyzers
Process Insights_Probes & Flow Cells

Questions? We’re here to help.