Teflon® Axial Flow Cell

Our GUIDED WAVE™ Teflon® Axial Flow Cell was developed for sample streams that are either extremely corrosive or intolerant to metal contamination, where even trace metal impurities can cause significant process problems. This long path length nonmetallic flow cell will meet these challenges with path lengths of 25 to 100 mm. The Teflon Axial Flow Cell was designed for Highly Corrosive Processes and/or Trace Metal Contamination Sensitivity.  Since no metal parts come in contact with the liquid stream, the design is ideal for processes where even parts per billion levels of metals contamination can create serious problems as in hf fab etching and cleaning steps. The Teflon Axial Flow Cell also performs well in the presence of extremely corrosive streams containing strong acids, bases, peroxides or halogenated compounds.

  • Non-Corrosive
  • No Metal
  • Excellent for Semiconductor Processes / Applications
  • Compatible with most Fiber Optic Based Spectroscopic Instruments

Why Choose A Teflon Axial Flow Cell?

Perhaps the most critical decision in designing a successful online analyzer system is the selection of the sample interface. While an insertion probe approach can often reduce installation costs, sometimes safety, servicing, and/or sample conditioning requirements make it necessary to integrate a sampling loop or slipstream. In those cases, a flow cell is the preferred optical interface device. A Teflon Axial Flow Cell design is called for when pathlengths exceed 20 mm and small flow volumes are required. It is a convenient, compact, rugged sample interface that is easy to install.

Flow cell performance strongly affects the overall system performance of a process spectrometer or a filter photometer. High optical efficiency and low sensitivity to environmental factors are essential to sensitive, reliable measurements. Achieving optimal system performance requires a flow cell that is insensitive to vibration, temperature and pressure changes. The Teflon Axial Flow Cell provides exceptional immunity to the environment.

Unique Flow Cell Design

The standard Teflon Axial Flow Cell has non-wetted metal components. It is available with a Teflon (PTFE) body with Teflon O-rings and either sapphire or fused silica windows depending on the spectral range. Teflon seals prevent leakage and protect the flow cells vital internal optics. Other major components are polyether ether ketone (PEEK), glass or fused silica lenses, and non-wetted viton O-rings.

Integration with Most Spectroscopic Analyzers

The Teflon Axial Process Flow Cell is manufactured to facilitate full integration with any fiber optic-based system configured with SMA 905 connectors. Keep in mind that operation with fibers having a core diameter of 400 to 600 micron will provide the best optical performance.

  • Non-corrosive, no metal design
  • High optical throughput for low noise spectroscopy
  • Suitable for liquids and vapors
  • Collimated beam for consistently accurate measurements
  • Reproducible pathlength permits servicing in the field
  • Compatible with 200 through 600 micron fiber
  • O-ring sealed optics to prevent ambient moisture infiltration
  • Compatible with most fiber optic-based spectroscopic instruments
  • Excellent for Semiconductor Processes / Application

High Optical Efficiency Makes the Teflon Axial Flow Cell Effective for Low Level Detection

The Teflon Axial Flow Cell provides exceptional optical performance. The Teflon Axial Flow Cell peak transmission exceeds 30% which is considerably higher than other flow cells on the market. That means more signal, lower measurement noise and lower limits of detection.

Custom Design Options

We work with you to develop the best solution for your particular process installation needs. We have a large variety of probes and flow cells as well as offering custom design services. Please contact us for help in selecting the correct style of probe or flow cell for the sample under consideration. If we do not have a probe or flow cell that meets your precise need, we have the experience and expertise to design one.



Designed for Highly Corrosive Processes and/or Trace Metal Contamination Sensitivity

Process Insights_Guided Wave Teflon Axial Process Flow Cell

GET A QUOTE TODAY | SERVICE | SALES | TRAINING

Americas +1.916.638.4944
EMEA +49 69 20436910
China/APAC +86 400 086 0106

info@process-insights.com


FLOW CELLS & PROBES

SST
GUIDED WAVE™ Gold Brazed Single-Sided Transmission Probe
Process Insights_Guided Wave_SST – Single-Sided Transmission Process Probe
SST LAB
GUIDED WAVE™ Gold Blaze Sealed QC Lab Transmission Probe

O-SST
GUIDED WAVE™ O-Ring Single Sided Transmission Probe
Process Insights_Guided Wave_O-SST O-Ring Single Sided Transmission Probe For Process Sampling
RTD-SST
GUIDED WAVE™ Temperature Resistant Detection Insertion Probe
G-SST Vapor Probe
GUIDED WAVE™ Probe for Precise Measurements of Hydrogen Peroxide & Water Vapor
Shuttle Process Probe
GUIDED WAVE™ Two Connected Transmission Probes
Turbidity Process Probe
GUIDED WAVE™ for Haze or Turbidity (NTU) Measurements with ClearView® db
MPFC Temperature Controlled Flow Cell
GUIDED WAVE™ Multi-Purpose Process Flow Cell for at-line FT-NIR
MPFC Multi-Purpose Process Flow Cell
GUIDED WAVE™ Flow Cell Used When Insertion Probe is Not Appropriate
Heated Multi-Purpose Flow Cell
GUIDED WAVE™ Flow Cell for Heating/Cooling Fluid to Maintain Temperature of Preconditioned Sample
Process Insights_Guided Wave_Heated Flow Cell
Axial Process Flow Cell
GUIDED WAVE™ Long Path Flow Cell for Process UV / VIS / NIR Photometry
Gas Flow Cell
GUIDED WAVE™ Flow Cell for Measuring Online Gases by Spectroscopy
HSFC High Safety Process Flow Cell
GUIDED WAVE™ Flow Cell for Extremely Hazardous Materials, Designed with Lead Prevention
Teflon PFA/PEEK Flow Cell
GUIDED WAVE™ Flow Cell for Sample Streams Incompatible w/ Metal Compounds (HF Semiconductor Baths)
Teflon Axial Flow Cell
GUIDED WAVE™ Flow Cell for Sample Streams in Highly Corrosive Processes | Trace Metal Contamination Sensitivity
Turbidity Flow Cell
GUIDED WAVE™ Flow Cell for At-Line Measurements Where a Direct Insertion Probe is Not Practical
Cuvette Holders
GUIDED WAVE™ Used in Rugged Lab Sample Interface
PROBE EXTRACTOR MECHANISM
GUIDED WAVE™ for Controlled Extraction/Insertion of In-Line Probe
THERMALLY STABLE NIR FIBER OPTIC CABLE
For Signal Stability & Low Noise in Remote Spectroscopy
To Top

OUR NIR-UV-VIS ANALYZER SOLUTIONS

NIR-O™

GUIDED WAVE™ Process Analyzer Spectrometer
Process Insights_guided wave- NIR-O_process analyzer

LAB NIR-O™

GUIDED WAVE™ Full Spectrum NIR Laboratory Analyzer Spectrometer
Process Insights_guided wave - Lab-NIRO-1

Stability Monitoring System

GUIDED WAVE™ UV-VIS Analyzer Spectrometer
Process Insights_guided wave- NIRO_web

M508plus™

GUIDED WAVE™ UV-VIS Analyzer Spectrometer
Process Insights_guided wave-M508-analyzer Closed-Door

LAB M508plus™ Benchtop

GUIDED WAVE™ Benchtop or LAB UV-VIS Analyzer Spectrometer
Process Insights_Guided Wave_Model 508plus benchtop

ClearView db™

GUIDED WAVE™ VIS-NIR Dual-Beam Analyzer Photometers
Process Insights_Guided Wave ClearView-db-enclosures-400x135

HPV™

GUIDED WAVE™ Hydrogen Peroxide Vapor Photometer System
Process Insights_Guided Wave Hydrogen Peroxide Vapor Analyzer HPVA Photometer Systems

APHA Color Analyzer

GUIDED WAVE™ VIS-NIR Dual-Beam Analyzer Photometer System
Process Insights_Guided Wave ClearView-db-enclosures-400x135

ASTM Color Analyzer

GUIDED WAVE™ VIS-NIR Dual-Beam Analyzer Photometer System
Process Insights_Guided Wave ClearView-db-enclosures-400x135

Saybolt Color Analyzer

GUIDED WAVE™ VIS-NIR Dual-Beam Analyzer Photometer
Process Insights_Guided Wave ClearView-db-enclosures-400x135

Turbidity Color Analyzer

GUIDED WAVE™ VIS-NIR Dual-Beam Analyzer Photometer

Probes & Flow Cells / Fiber & Accessories

GUIDED WAVE™ Accessories for NIR-UV-VIS
Process Insights_Probes & Flow Cells

OUR FTIR FT-NIR PROCESS & LAB ANALYZERS

RovIR™

ANALECT® FTIR Portable Analyzer for Real-Time Dynamic Monitoring of Pilot Scale Reaction Chemistries & Continuous Process Streams
ANALECT® RovIR

RefinIR™

ANALECT® Fully Integrated Laboratory Autosampler & FTIR Instrument Designed To Analyze Heavy & Light Hydrocarbons Including Crude Oil & Gasoline
ANALECT® RefinIR

Hydrocarbon Smart System™

ANALECT® On-Line, Real-Time FTIR Monitoring of Refinery & Petrochemical Process Streams in Hazardous Areas
ANALECT® Hydrocarbon SmartSystem®

Diamond MX™

ANALECT® FT-NIR On-Line Analyzer for Round-The-Clock Multi-Point Continuous Air Monitoring for a Variety of Applications
ANALECT® Diamond MX

Diamond 20™

ANALECT® FTIR/NIR Analyzer for Operation in Rugged At-Line Environments and on the Laboratory Bench
Process Insights_ANALECT® Diamond 20

PCM 1000™

ANALECT® Mid IR Direct Coupled Analyzer for On-Line, In-Situ & At-Line Monitoring of Batch & Continuous Processes Measuring Physical, Chemical & Compositional Properties of Liquids, Solids & Gases
ANALECT PCM 1000

PCM 5000™

ANALECT® Mid-Infrared Analyzer for Measuring Physical, Chemical & Compositional Properties of Liquids, Solids & Gases
ANALECT PCM 5000

EVM™

ANALECT® FTIR Monitoring Analyzer for Real-Time Analysis of Organic & Inorganic Compounds with ppb to % Level Detection.
ANALECT® EVM
To Top

Questions? We’re here to help.