Teflon Axial Process Flow Cell

Highly Efficient and Reliable Measurements

Our Guided Wave Teflon® Axial Flow Cell was developed for sample streams that are either extremely corrosive or intolerant to metal contamination, where even trace metal impurities can cause significant process problems. This long path length nonmetallic flow cell will meet these challenges with path lengths of 25 to 100 mm. The Teflon Axial Flow Cell was designed for Highly Corrosive Processes and/or Trace Metal Contamination Sensitivity.  Since no metal parts come in contact with the liquid stream, the design is ideal for processes where even parts per billion levels of metals contamination can create serious problems as in hf fab etching and cleaning steps. The Teflon Axial Flow Cell also performs well in the presence of extremely corrosive streams containing strong acids, bases, peroxides or halogenated compounds.

  • Non-Corrosive
  • No Metal
  • Excellent for Semiconductor Processes / Applications
  • Compatible with most Fiber Optic Based Spectroscopic Instruments

Why Choose A Teflon Axial Flow Cell?

Perhaps the most critical decision in designing a successful online analyzer system is the selection of the sample interface. While an insertion probe approach can often reduce installation costs, sometimes safety, servicing, and/or sample conditioning requirements make it necessary to integrate a sampling loop or slipstream. In those cases, a flow cell is the preferred optical interface device. A Teflon Axial Flow Cell design is called for when pathlengths exceed 20 mm and small flow volumes are required. It is a convenient, compact, rugged sample interface that is easy to install.

Flow cell performance strongly affects the overall system performance of a process spectrometer or a filter photometer. High optical efficiency and low sensitivity to environmental factors are essential to sensitive, reliable measurements. Achieving optimal system performance requires a flow cell that is insensitive to vibration, temperature and pressure changes. Guided Wave’s Teflon Axial Flow Cell provides exceptional immunity to the environment.

Unique Flow Cell Design

The standard Teflon Axial Flow Cell has non-wetted metal components. It is available with a Teflon (PTFE) body with Teflon O-rings and either sapphire or fused silica windows depending on the spectral range. Teflon seals prevent leakage and protect the flow cells vital internal optics. Other major components are polyether ether ketone (PEEK), glass or fused silica lenses, and non-wetted viton O-rings.

Integration with Most Spectroscopic Analyzers

Like other Guided Wave optical probes and flow cells, the Teflon Axial Process Flow Cell is manufactured to facilitate full integration with any fiber optic based system configured with SMA 905 connectors. Keep in mind that operation with fibers having a core diameter of 400 to 600 micron will provide the best optical performance.

Features — A Simple, Serviceable Design

  • Non-corrosive, no metal design
  • High optical throughput for low noise spectroscopy
  • Suitable for liquids and vapors
  • Collimated beam for consistently accurate measurements
  • Reproducible pathlength permits servicing in the field
  • Compatible with 200 through 600 micron fiber
  • O-ring sealed optics to prevent ambient moisture infiltration
  • Compatible with most fiber optic-based spectroscopic instruments
  • Excellent for Semiconductor Processes / Application

High Optical Efficiency Makes the Teflon Axial Flow Cell Effective For Low Level Detection

Like other Guided Wave optical probes and flow cells, the Teflon Axial Flow Cell provides exceptional optical performance. The Teflon Axial Flow Cell peak transmission exceeds 30% which is considerably higher than other flow cells on the market. That means more signal, lower measurement noise and lower limits of detection.

Custom Design Options

We work with you to develop the best solution for your particular process installation needs. We have a large variety of probes and flow cells as well as offering custom design services. Please contact us for help in selecting the correct style of probe or flow cell for the sample under consideration. If we do not have a probe or flow cell that meets your precise need, we have the experience and expertise to design one.


    For a complete range of applications, system options, and service, please contact us.

    SERVICE | SALES | TRAINING

    Phone: +1.916.638.4944

    Fax: +1.916.635.8458

    gwsales@guided-wave.com

    gwsupport@guided-wave.com



    Designed for Highly Corrosive Processes and/or Trace Metal Contamination Sensitivity

    Process Insights_Guided Wave Teflon Axial Process Flow Cell

    Other SPECTROMETERS, FLOW CELLS & PROBES for Industrial Applications

    NIR-O

    Guided Wave Process Analyzer Spectrometer

    LAB NIR-O

    Guided Wave Full Spectrum NIR Laboratory Analyzer Spectrometer

    Stability Monitoring System

    Guided Wave UV-VIS Analyzer Spectrometer

    Process Insights_guided wave- NIR-O_process analyzer

    M508plus

    Guided Wave UV-VIS Analyzer Spectrometer

    M508plus Benchtop

    Guided Wave Benchtop UV-VIS Analyzer Spectrometer

    Process Insights_Guided Wave_Model 508plus benchtop

    ClearView db

    Guided Wave VIS-NIR Dual-Beam Analyzer Photometers

    Hydrogen Peroxide Vapor HPV

    Guided Wave Analyzer System Photometer

    APHA Color Analyzer

    Guided Wave VIS-NIR Dual-Beam Analyzer Photometer System

    ASTM Color Analyzer

    Guided Waver VIS-NIR Dual-Beam Analyzer Photometer System

    Saybolt Color Analyzer

    Guided Waver VIS-NIR Dual-Beam Analyzer Photometer

    Turbidity Color Analyzer

    Guided Wave VIS-NIR Dual-Beam Analyzer Photometer

    SST Probe

    Guided Wave Single-Sided Transmission Process Probe

    O-SST Probe

    Guided Wave O-Ring Single-Sided Transmission Process Probe

    RTD-SST Probe

    Guided Wave Resistance Temperature Detector SST Probe

    Turbidity Process Probe

    Guided Wave Corrosion-Resistant Process Probe

    Shuttle Process Probe

    Guided Wave Process Probe for Monitoring Liquid Samples

    G-SST Probe

    Guided Wave Vapor Process Probe

    MPFC

    Guided Wave Multi-Purpose Process Flow Cell

    MPFC Heated

    Guided Wave Heated Multi-Purpose Process Flow Cell

    Axial Process Flow Cell

    Guided Wave Process Flow Cell

    Gas Process Flow Cell

    Guided Wave Transmission Gas Process Flow Cell

    High Safety Process Flow Cell

    Guided Wave Process Flow Cell For Measuring Hazardous or Corrosive Gases

    Teflon Process Flow Cell

    Guided Wave Process Flow Cell

    Teflon PFA/PEEK Process Flow Cell

    Guided Wave Process Flow Cell

    Turbidity Process Flow Cell

    Guided Wave Process Flow Cell

    Questions? We’re here to help.