Model 473 Chilled Mirror Dew Point Hygrometer
Humidity Calibration & Validation | Climatic Chamber Validation
Model 473 Chilled Mirror Dew Point Hygrometer
Humidity Calibration & Validation | Climatic Chamber Validation
Validating a climatic chamber or calibrating a humidity system requires accurate measurement of the actual conditions at the point of use. The MBW CALIBRATION™ Model 473™ Chilled Mirror Hygrometer combines precise dew/frost point measurement with temperature measurement and flexible cable-mounted measuring heads that can be positioned directly within the test environment.
Designed for climatic chamber validation, humidity generator calibration, RH transfer standards, weather-station calibration, engine test cells and environmental testing, the Model 473 provides stable, repeatable measurements with the flexibility to match the measuring head to the application.
Talk to a Humidity & Calibration Expert
- Highly precise chilled mirror dew point technology
- Cable mounted dew point and temperature measurement
- Aspirated and direct insertion measuring heads
- Barometric pressure measurement options
- Intuitive color touch screen user interface
- User verifiable calibration
All 473 instruments are delivered as complete measurement sets that include:
- 473 display
- Measuring head
- Measuring head cable
- Pt-100 temperature probe and cables
- Factory calibration certificate*
- IP65 transport case
In combination with the T12 multichannel thermometer, the 473 is particularly well suited to climatic chamber validation projects.
* For a small additional cost, the factory calibration can be upgraded to ISO17025 accredited calibration
What Is the MBW Model 473?
The MBW Model 473 is a high-precision chilled mirror hygrometer designed to measure dew point, frost point, temperature and calculated relative humidity for climatic chamber validation, humidity calibration and environmental testing.
Unlike conventional RH probes, chilled mirror technology directly determines dew or frost point from condensation on a temperature-controlled mirror. The Model 473 combines that direct measurement with a precision Pt-100 temperature probe, enabling accurate determination of relative humidity under test conditions.



SALES | TRAINING INQUIRIES
AMERICAS: info.americas@process-insights.com
EMEAI (includes India): info.emeai@process-insights.com
APAC: info.apac@process-insights.com
CHINA: info.cn@process-insights.com

Why Use a Chilled Mirror Hygrometer for Chamber Validation?
Don’t Just Trust the Chamber Display. Verify the Actual Conditions.
Climatic and environmental chambers depend on accurate temperature and humidity control. However, the chamber’s control sensor tells you what its own sensor is measuring—not necessarily the exact conditions experienced by the product or device under test.
An independent chilled mirror reference provides a separate measurement of actual chamber humidity. The Model 473’s cable-mounted dew-point and temperature sensors can be positioned directly within the working volume, helping users identify:
- Temperature gradients
- Humidity gradients
- Control-sensor deviations
- Chamber uniformity issues
- RH measurement errors
- Changes between calibration points
Process Insights specifically positions the 473 for climatic chamber validation and notes that all Model 473 instruments include a temperature probe used with dew-point measurement to calculate relative humidity.
Measure the Physical Condensation Point—not an Inferred Sensor Response.
The Model 473 uses chilled mirror condensation technology. Water vapor condenses onto a temperature-controlled mirror. Optical electronics detect the condensation, while a precision platinum resistance thermometer embedded in the mirror measures its temperature. That temperature represents the dew or frost point of the gas. This direct measurement principle provides highly precise, stable and repeatable results across demanding temperature and humidity conditions.
Why It Matters
- High precision — Suitable for calibration and validation.
- Excellent repeatability — Confidence when repeating chamber tests.
- Long-term stability — Reduces uncertainty associated with sensor drift.
- Direct measurement — Dew point is determined from a physical condensation event.
- Wide application range — Different 473 measuring heads address different test conditions.
One Model 473 Platform. Multiple Measuring Heads.
Choose the Measuring Head That Matches Your Application
The SH2 is positioned for climatic chambers and humidity generators; the RP2 for direct insertion into moving air; and the SHX for high-temperature environments up to 125°C.
Model 473-SH2
For Climatic Chambers & Humidity Generators
The 473-SH2 uses a cable-mounted chilled mirror measuring head with an integrated sample-flow fan.
It is designed for applications including:
Climatic chamber validation
RH generator transfer standards
Calibration references
Engine test cells
Process validation
The SH2 has an integrated temperature-probe capability and easy mirror access for cleaning. Its stated frost/dew-point range is −20 to +70°C, with frost/dew-point accuracy of ≤±0.1°C and reproducibility of ≤±0.05°C.
Model 473-RP2
For Direct Measurement in Moving Air
The 473-RP2 uses a compact probe-style chilled mirror head designed for direct insertion into environments with moving air.
Typical applications include:
RH generators
Climatic chambers
Manufacturing processes
Air ducts
The RP2 can also carry its calibrated temperature probe directly on the measuring head, helping minimize errors caused by temperature gradients between the humidity and temperature measurement locations.
Model 473-SHX
For High-Temperature Humidity Measurement
The 473-SHX extends the Model 473 platform into demanding high-temperature test environments.
Its optical components, electronics, fan and materials are designed to operate in test conditions up to 125°C.
Typical applications include:
HALT/HASS chambers
High-temperature climatic chambers
Fuel-cell testing
Dryer-performance testing
Environmental testing
The SHX provides a frost/dew-point range of −30 to +99°C, temperature measurement from −50 to +125°C, frost/dew-point accuracy ≤±0.1°C and reproducibility ≤±0.05°C under the specified operating conditions.
Climatic Chamber Validation
Know the Conditions Your Product Is Actually Experiencing.
I’d make this the largest application section because it is where I think the 473 can build a particularly strong organic-search identity. The Model 473 is designed for independent humidity and temperature measurement during climatic and environmental chamber validation. With cable-mounted measuring heads, the measurement can be made within the chamber’s working volume instead of relying solely on the chamber’s built-in control sensor.
When combined with the MBW T12 multichannel thermometer, the Model 473 is particularly suited to multi-point climatic chamber validation.
Use the Model 473 to evaluate:
- Temperature
- Dew point
- Frost point
- Relative humidity
- Chamber stability
- Chamber uniformity
- Control-sensor performance
Process Insights specifically identifies the Model 473 for climatic chamber validation to IEC 60068.
Can I Trust the Chamber’s Built-In RH Sensor?
Customer Challenge – “Is the chamber actually at 80% RH—or does its control sensor just say it is?”
Model 473 Solution
Use an independent chilled mirror reference to directly measure dew point and temperature and verify the actual chamber humidity.
Temperature Gradients Are Affecting RH
Customer Challenge – “Are we measuring temperature and humidity at the same point?”
Small temperature differences can create significant differences in calculated RH.
Model 473 Solution
Cable-mounted measuring heads and temperature probes allow measurement close to the actual test point. The RP2 specifically allows the temperature probe to be mounted directly on the measuring head or positioned at the instrument under test.
RH Probe Drift Is Increasing Calibration Uncertainty
Customer Challenge – “How much of our calibration uncertainty is coming from the reference RH probe?”
Model 473 Solution
Use direct chilled mirror dew-point measurement with precision temperature measurement as an independent humidity reference. Process Insights positions the 473 as an RH-generator transfer standard intended to minimize uncertainty from drift, hysteresis and repeatability.
ur Test Conditions Are Too Hot for Standard Instrumentation
Customer Challenge – “How do we validate humidity when chamber temperatures reach 125°C?”
Model 473 Solution
The 473-SHX is specifically designed with high-temperature components for operation in test conditions up to 125°C.