Series 3000 Trace Oxygen Analyzer for Continuous Industrial Gas Monitoring
Series 3000
Trace Oxygen Analyzer for Continuous Industrial Gas Monitoring
Even small amounts of oxygen contamination can reduce product quality, damage catalysts, increase oxidation, and compromise gas purity.
The ALPHA OMEGA INSTRUMENTS™ Series 3000™ Trace Oxygen Analyzer delivers continuous, high-accuracy oxygen measurement from below 1 ppm to 10,000 ppm, helping manufacturers monitor oxygen continuously instead of relying on delayed manual testing. Featuring a long-life electrochemical sensor, automatic ranging, configurable alarms, and optional CO₂-resistant sensing, the Series 3000 helps improve product quality, increase process reliability, and reduce maintenance costs.
What Is a Trace Oxygen Analyzer?
A trace oxygen analyzer continuously measures oxygen at very low concentrations (parts per million) to verify gas purity, monitor inert atmospheres, protect catalysts, and prevent oxidation in industrial processes.
Continuous trace oxygen monitoring allows operators to:
- Detect contamination immediately
- Improve gas quality
- Protect sensitive manufacturing processes
- Reduce manual sampling
- Improve process control
- Support quality assurance
Why Choose the Series 3000?
Long-Life Electrochemical Sensor
Designed to provide significantly longer service life than many conventional fuel-cell oxygen sensors while reducing maintenance and operating costs.
Wide Measurement Range
Measure oxygen concentrations from below 1 ppm to 10,000 ppm using single- or multi-range configurations with optional automatic range switching.
Optional CO₂-Resistant Sensor
Ideal for applications where carbon dioxide may shorten the life of conventional electrochemical oxygen sensors.
Continuous Process Monitoring
Receive immediate oxygen measurements with configurable alarms, analog outputs, and relay contacts for PLC, DCS, or SCADA integration.
Low Cost of Ownership
Factory calibration, sealed sensor design, long sensor life, and reduced maintenance requirements help lower total operating costs
Key Features
- Trace oxygen measurement from below 1 ppm to 10,000 ppm
- Long-life electrochemical sensor
- Optional CO₂-resistant sensor
- Automatic ranging (three-range models)
- 4–20 mA and 0–2 V outputs
- Three configurable oxygen alarm relays
- Audible and visual alarms
- Universal AC or 18–32 VDC power
- Factory calibrated
- Optional sample conditioning accessories
- General-purpose enclosure
Series 3000 vs. Other Oxygen Measurement Solutions
| Application | Recommended Product |
|---|---|
| Continuous trace oxygen monitoring | Series 3000 |
| Portable trace oxygen measurements | Series 3520 |
| Continuous percent oxygen | Series 2000 |
| Portable percent oxygen | Series 2520 |
| PLC/DCS integration without local display | Series 3500 / 3510 |
| Oxygen deficiency safety monitoring | Series 1300 |
Oxygen Monitors Resources and Manuals
Need service or calibration for your oxygen analyzer? No problem. We are ready to assist you with any technical or service-related inquiries. Just complete our Oxygen Monitor RMA.
SALES | TRAINING INQUIRIES
AMERICAS: info.americas@process-insights.com
EMEAI (includes India): info.emeai@process-insights.com
APAC: info.apac@process-insights.com
CHINA: info.cn@process-insights.com

Applications
Industrial Gas Production
Verify oxygen purity in:
- Nitrogen
- Hydrogen
- Argon
- Helium
- Specialty gases
Semiconductor Manufacturing
Monitor trace oxygen in:
- Bulk gas systems
- Specialty gas distribution
- Process tools
- Glove boxes
- Ultra-high-purity gas systems
Pharmaceutical Manufacturing
Monitor inert gas blanketing, reactor purging, and packaging operations to maintain product quality.
Food & Beverage Packaging
Measure oxygen during modified atmosphere packaging (MAP) and nitrogen blanketing to extend shelf life.
Petrochemical & Chemical Processing
Protect catalysts, monitor inerting systems, and improve reaction control.
Heat Treating & Welding
Measure oxygen in furnace atmospheres and shielding gases to reduce oxidation and improve product quality.
Research & Laboratories
Ideal for glove boxes, environmental chambers, anaerobic chambers, and laboratory gas systems.

COMPARISON CHART
| Product Series | 1000 | 1300 | 2000 | 3000 | 3500 | 3510 | 3520 | OXY-SEN |
|---|---|---|---|---|---|---|---|---|
| Oxygen Ranges | ||||||||
| 0-10,000 PPM | X | |||||||
| 0-5,000 PPM | X | X | ||||||
| 0-1,000 PPM | X | |||||||
| 0-100% | X | X | ||||||
| 0-30% | X | X | ||||||
| Multiple Range Capabilities | 3 | 4 | ||||||
| Confined Space Safety Monitors | X | X | ||||||
| Features & Options | ||||||||
| Analog Recorder Outputs | 2 | 2 | 2 | 2 | 1 | 1 | 2 | |
| Number of Alarms | 3 | 9 | 3 | 3 | ||||
| Oxygen Alarm Relays | 3 | 9 | 3 | 3 | ||||
| AC/DC Powered | X | X | X | X | X | X | ||
| AC Powered with Optional Battery Operation | X | |||||||
| Loop Powered Transmitter (no display) | X | |||||||
| Blind Transmitter | X | X | ||||||
| Standard RS232 | X | |||||||
| Optional Remote Sensor | X | |||||||
| Optional Sampling Systems Components | X | X | X | X | X | X |