Skip to main content

NitriTox TOXIMETER

Reliable NITRITOX Toximeter for Monitoring Toxicity Levels in Industrial Wastewater

Ideal for Harsh Wastewater and Environmental Applications

The LAR™ NitriTox™ toximeter is an advanced online water analyzer, specifically designed to provide real-time toxicity monitoring in wastewater treatment plants, industrial processes, and environmental monitoring systems. By leveraging highly sensitive bioluminescent bacteria, the NitriTox accurately detects and measures toxic pollutants in water based on changes in bacterial luminescence triggered by harmful substances. To learn more, contact us today.  Contact us today.

Moreover, with a rapid measuring interval of less than 5 minutes, the NitriTox allows for early detection and timely countermeasures against pollution events. As a result, operators benefit from three customizable alarm levels, enabling proactive protection of water systems and ensuring regulatory compliance.

Key Features of the NitriTox Toximeter

  • Continuous online monitoring of water toxicity
  • Fast response time – results in under 5 minutes
  • Bioluminescent bacterial detection of toxic substances
  • Customizable alarm thresholds for efficient decision-making
  • Reliable performance in real-world industrial and environmental settings

Typical Applications

Wastewater Treatment Plants

  • Monitor toxicity levels in effluent
  • Ensure discharge complies with environmental regulations
  • Protect aquatic ecosystems from harmful pollutants

Industrial Wastewater Monitoring

Environmental Monitoring

  • Track toxicity in surface water, groundwater, and soil samples
  • Detect environmental contamination
  • Assess the effectiveness of remediation efforts

Research & Development

  • Study toxic effects of various substances
  • Support eco-toxicological studies and environmental impact assessments

features & benefits

  • Measurement range: 0 – 100% Toxicity
  • Fast Response Time: 5 – 10 minutes (depending on application)
  • Toxicity monitoring
  • Self-regenerating culture of nitrifying bacteria
  • Highly sensitive
  • No memory effects
  • Low operational cost
  • High reproducibility
  • No purchase of test organisms required
  • According to DIN EN ISO 9509:2006

FAST & ROBUST TOXICITY ANALYsis

he NitriTox instrument uses bioluminescent bacteria to measure the toxicity of water samples. It works by detecting changes in the light (luminescence) the bacteria produce when exposed to toxic substances.

To begin with, a small amount of bioluminescent bacteria is added to a sample chamber that holds the water being tested. The bacteria used are typically a strain of Vibrio fischeri, which naturally emits light when affected by certain chemicals.

Next, the NitriTox uses a photomultiplier tube to measure the light given off by the bacteria. This device detects the level of luminescence and converts it into an electrical signal.

If toxic substances are present in the water, the light produced by the bacteria will decrease. This drop in luminescence indicates the presence of toxicity.

Finally, the NitriTox calculates a toxicity score based on how much the luminescence is reduced. This score helps evaluate the severity of toxicity in the water sample.

To Top
toximeter water analyzer

NO FURTHER PURCHASES NECESSARY

Firstly, it is not necessary to purchase or externally cultivate test organisms, such as fish or daphnia. Secondly, the toxicity analyzer is extremely low in maintenance because the bacteria mass constantly proliferates on its own.


Reliable TRUE TOC COD BOD & Water Analyzers for Every Industry and Every Type of Water

QuickTOCultra™ TRUE TOC Water Analyzer using High Temperature Method

LAR™ Water analyzer for TRUE TOC® in harsh environmental monitoring, municipal facilities, and industrial manufacturing applications
LAR QUICK TOC ULTRA WATER ANALYZER

QuickTONultra™ TNb Water Analyzer with Chemiluminescence Technology

LAR™ Water analyzer for determining total nitrogen bound (TNb) in wastewater and process water applications
LAR QUICK TON ULTRA WATER ANALYZERS

QuickCODultra™ COD Water Analyzer using UV-Activated Persulfate

LAR™ Water analyzer to measure chemical oxygen demand (COD) in water samples including difficult-to-oxidize compounds such as humic acids and lignin
LAR QUICK COD ULTRA WATER ANALYZERS

QuickTOCairport™ Run-Off Deicing Water Analyzer for airport water applications

LAR™ Water analyzer for Total Organic Carbon (TOC) and Chemical Oxygen Demand (COD) in airport applications
LAR QUICK TOC FOR AIRPORT APPLICATIONS

QuickCODlab™ COD Lab Water Analyzer for Laboratories

LAR™ Water analyzer to determine COD without potassium dichromate, sulfuric acid, mercury, or other hazardous reagents
Process Inisights_LAR QuickCODlab water analyzer for laboratories

BioMonitor™ Online Toximeter for Organic or Inorganic Compounds BOD

LAR™ Toximeter used in wastewater treatment plants, industrial process monitoring, and environmental monitoring.
Process Insights_LAR_BioMonitor_wwt water analyzer

Nitritox™ Online Toximeter for Measuring Toxicity in Water

LAR™ Toximeter used in wastewater treatment plants, industrial processes, and environmental monitoring systems
Process Insights_LAR_Toximeter NitriTox

ToxAlarm™ Online Toximeter for Municipal Water Treatment, Industrial Wastewater Monitoring & Environmental Protection

LAR™ Toximeter for monitoring drinking water, surface water, and groundwater
Process Insights_LAR_ToxAlarm
To Top